Abstract

A Total Reflection X-Ray Fluorescence (TXRF) methodology, employing burn-leach test, was developed to assess the quality of SiC layer in tristructural isotropic (TRISO) coated UO2 particles prepared in BARC. The coated particles were heated at 1,123 K for about 96 h to constant weight. The calcined particles, thus obtained, were then heated in suprapure concentrated nitric acid. The supernatant was analysed for trace elements by TXRF. No uranium was detected in this supernatant solution. The study demonstrates the good quality of SiC layer and applicability of TXRF for burn leach test of TRISO coated UO2 particles prepared.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.