Abstract

A simplified technique based on the gamma function was developed to determine the effective renal plasma flow (ERPF) by [131I]hippuran clearance. The method requires only one blood sample in addition to standard renography and the calculations can be performed on a small computer. A close correlation was found between the ERPF values obtained by the application of the gamma function and the values yielded by the conventional bi-exponential approach. The present method is well suited for clinical routine use in connection with standard renography.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.