Degradation of epichlorohydrin was investigated using subcritical water oxidation method in the presence of hydrogen peroxide. Degradation rate was monitored by means of total organic carbon (TOC) analysis. The central composite design was used to determine optimal TOC removal conditions and modelling experimental process. The effects of all experimental variables (temperature, oxidant concentration of hydrogen peroxide and treatment time) on the TOC removal rates were evaluated and the theoretical prediction model was proposed. Reliability of the employed model was evaluated using ANOVA. F value and the p-value of the model were found to be 84.60 and <0.0001, respectively. 93.78 % of TOC removal was achieved in the degradation of epichlorohydrin at 373 K of temperature and 75 min of treatment time using 90 mM of H2O2.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.