Abstract

This paper deals with the topic of detecting and classifying one of the most common faults of permanent magnet synchronous motor - interturn short circuits. The idea of using spectral analysis of the stator phase current signal and its envelope to symptom extraction and the support vector machine to classify the fault is proposed. To assess the effectiveness of the proposed diagnostic method, experimental tests were conducted. The object of the experimental verification was a 2.5kW permanent magnet synchronous motor operating in a closed-loop control structure. The impact of changes in motor operating conditions on the effectiveness of failure classification has also been tested.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.