Abstract

AbstractAn industrial‐scale dead‐end ultrafiltration system was optimized using statistically designed experiments. Given a certain level of pollutant, a two‐level full factorial design and a central composite design were used to optimize the filtrate production of a single 8‐inch industrial ultrafiltration membrane while manipulating the levels of four factors: feed pressure, backwash pressure, forward filtration time, and backwash time. Analysis of variance and residual analysis were used to validate and check the adequacy of the developed regression models. The optimal levels were later validated experimentally. The predicted filtrate production was in reasonable agreement with the experimental data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.