The highly-changing concept of Power Quality (PQ) needs to be continuously reformulated due to the new schemas of the power grid or Smart Grid (SG). In general, the spectral content is characterized by their averaged or extreme values. However, new PQ events may consist of large variations in amplitude that occur in a short time or small variations in amplitude that take place continuously. Thus, the former second-order techniques are not suitable to monitor the dynamics of the power spectrum. In this work, a strategy based on Spectral Kurtosis (SK) is introduced to detect frequency components with a constant amplitude trend, which accounts for amplitude values’ dispersion related to the mean value of that spectral component. SK has been proven to measure frequency components that follow a constant amplitude trend. Two practical real-life cases have been considered: electric current time-series from an arc furnace and the power grid voltage supply. Both cases confirm that the more concentrated the amplitude values are around the mean value, the lower the SK values are. All this confirms SK as an effective tool for evaluating frequency components with a constant amplitude trend, being able to provide information beyond maximum variation around the mean value and giving a progressive index of value dispersion around the mean amplitude value, for each frequency component.

Highlights

  • The current electric power system requires extensive control power electronics within all the stages, from the energy generation stage to consumption units [1,2,3,4]

  • The Spectral Kurtosis (SK) estimator shows flexible detection capacity, based on points’ concentration around the mean value, and not if only one value is outside the threshold, which can cause false detections

  • This implies a detection of a big amplitude change with a short length or a small amplitude change with a long length

Read more

Summary

Introduction

The current electric power system requires extensive control power electronics within all the stages, from the energy generation stage to consumption units (e.g., inverters, rectifiers, DC/DC converters, etc.) [1,2,3,4]. This work focuses on the detection of frequency components (sub-harmonics, harmonics, or inter-harmonics) with a constant amplitude trend, which implies a permanent distortion; otherwise, a transitory state may be present during the averaged time or the amplitude values may change. DFT will be compared with Spectral Kurtosis (SK), a fourth-order technique (HOS), which shows a very good capacity for different stationary signals [15,16] It has been previously used in PQ evaluation in [17,18,19] (in addition to other fields, such as insect detection based on vibration [20] or the main application up to now, which is fault detection in rotatory machines [21]), where SK was used for the detection of PQ events, as well as their characterization.

Spectral Kurtosis
Arc Furnace Current Signal
Power Signal
Findings
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call