Abstract

The article defines the list of technical characteristics of armaments and military equipment (ARM), the value of which is measured using phase methods. An analysis of known methods that have found wide application in measuring technology, which is designed to determine the technical characteristics associated with the measurement of phase shift during the development, manufacture and operation of weapons. Based on this analysis, it was determined that the measuring systems are designed to determine the phase shift of two harmonic signals in their composition have two channels of information transmission. This architecture of the implementation of measuring systems leads to the fact that a significant impact on the accuracy of the proposed measurement problem, makes a component of the error due to the phase symmetry of the signal transmission channels, as well as internal and external noise. As an alternative approach to solving the measurement problem of determining the phase shift of two harmonic signals, which will significantly reduce the error component due to phase asymmetry of information transmission channels, it is proposed to use the signal obtained by summing harmonic signals after full-wave transformation followed by spectral analysis. In order to implement the above approach, a measurement problem was set to determine the phase shift of two harmonic signals, using spectral analysis of the signal obtained by summing the harmonic signals after their full-wave transformation. A list of assumptions required for the synthesis of analytical relations that establish the relationship between the spectra of phases and amplitudes (power) of the signal obtained by summing harmonic signals after their full-wave transformation and phase shift of two harmonic signals. Analytical relationships are proposed that establish the relationship between the above characteristics. It is shown that the values of the spectrum of phases and amplitudes, which are calculated using the proposed expressions, differ from the values obtained in the calculations using the Fourier series coefficients, not more than 0.1%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.