Abstract

To evaluate the curative efficacy of self-made fine-tuning setting in the process of femoral distal implantation of intramedullary nail. From October 2015 to October 2017, 66 cases of femoral shaft fracture were treated with anterograde interlocking intramedullary nail including 45 males and 21 females with a mean age of(37.21±11.18) years old. Among them, 36 cases were treated with the manufacture's aiming device and self-made fine-tuning setting (research group), other 30 cases were treated with the manufacture's aiming device(control group). The mean operation time, the times of C-arm scan in surgery, the post-operation complications and the fracture union were observed and compared in two groups. Sixty-two cases acquired 8 to 15 months with a mean time of 12.4 months follow-up visit. The post-operation complications and the fracture union between the two groups had no significant difference(P>0.05), the mean operation time and the times of C-arm scan in surgery had statistically significant difference(P<0.05). Self-made fine-tuning setting in the process of femoral interblocking intramedullary nail could shorten operation time and reduce the the times of C-arm scan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.