Abstract

BackgroundComputed tomography (CT) is the preferred imaging technique for the evaluation of COVID-19 pneumonia. However, it is not suitable as a monitoring tool for pregnant women because of the risk of ionizing radiation damage to the fetus as well as the possible infection of others. In this study, we explored the value of bedside lung ultrasound (LUS) as an alternative to CT for the detection and monitoring of lung involvement in pregnant women with COVID-19.MethodsClinical and LUS data of 39 pregnant women with COVID-19 were retrospectively reviewed. All LUS and CT images were analyzed to summarize the findings and calculate LUS scores and CT scores for each patient. LUS findings were compared with CT, and correlation between LUS scores and CT scores was evaluated.ResultsAmong the 39 pregnant women, there were 6 mild-type cases, 29 common-type cases, 4 severe-type cases, and no critical-type cases. The most common LUS findings of COVID-19 pneumonia in pregnant women were various grades of multiple B-lines (84.6%), thickened and irregular pleural lines (71.8%), pleural effusion (61.5%) and small multifocal consolidation limited to the subpleural space (35.9%). The mean LUS score at admission was 0 points in mild-type cases, 10.6 points in common-type cases and 15.3 points in severe-type cases (P < 0.01). The correlation between LUS scores and CT was 0.793. All patients were clinically cured and each underwent an average of three LUS follow-ups during hospitalization. The mean LUS score at discharge was 5.6 points lower than that at admission. The consistency of LUS and chest CT during follow-up was 0.652.ConclusionsQuantitative LUS scoring can effectively instead of CT for detecting and monitoring of COVID-19 pneumonia in pregnant women and protect fetuses from the risk of ionizing radiation.

Highlights

  • Computed tomography (CT) is the preferred imaging technique for the evaluation of COVID-19 pneumonia

  • The most common lung ultrasound (LUS) findings of COVID-19 pneumonia in pregnant women were increased B-lines to different degrees (33/39), thickening and irregularity of the pleural line (28/39), pleural effusions (24/ 39), and small multifocal consolidation limited to the subpleural space (14/39)

  • Our study confirmed that the most common LUS findings of COVID-19 pneumonia in pregnant women were various grades of multiple B-lines (84.6%), thickened and irregular pleural lines (71.8%), pleural effusion (61.5%) and small multifocal consolidation limited to the subpleural space (35.9%)

Read more

Summary

Introduction

Computed tomography (CT) is the preferred imaging technique for the evaluation of COVID-19 pneumonia. It is not suitable as a monitoring tool for pregnant women because of the risk of ionizing radiation damage to the fetus as well as the possible infection of others. Severe pneumonia and acute respiratory distress syndrome are the leading causes of death in COVID-19 patients. And accurate evaluation of lung lesions is very important in the treatment of patients with COVID-19. Chest computed tomography (CT) represents the gold standard to assess the evaluate lung lesions, it is not an ideal monitoring tool for pregnant patients because of the risk of ionizing radiation to the fetus.

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call