Abstract
Objective: To investigate the application of pulse contour cardiac output (PiCCO) monitoring technology in fluid resuscitation of severe burn patients in shock period. Methods: From January 2015 to December 2019, 33 patients with severe burns who were hospitalized in Guangzhou Red Cross Hospital, meeting the inclusion criteria, were recruited into a retrospective cohort study with their clinical information collected. The patients were divided into PiCCO monitoring group with 15 cases (13 males and 2 females, aged (43±13) years) and routine monitoring group with 18 cases (14 males and 4 females, aged (39±9) years) according to the monitoring method used. After admission, all the patients were rehydrated following the rehydration formula of the Third Military Medical University for shock period. In routine monitoring group, the fluid resuscitation of patients was performed by monitoring indicators such as urine volume and blood pressure, while PiCCO monitoring was performed among patients in PiCCO monitoring group, and their fluid resuscitation was guided by the patient's condition and the hemodynamic parameters (without pursuing normal levels of the parameters) of PiCCO monitoring on the basis of normal monitoring indicators in routine monitoring group. The colloids coefficients, the electrolyte coefficients (compared with the corresponding rehydration formula value of 0.75 mL·kg(-1)·% total body surface area (TBSA)(-1) of the Third Military Medical University for shock period during the first 24 h post injury), the total rehydration coefficients, and the urine volumes during the first and second 24 h post injury, the lactic acid level, the base excess level, and the oxygenation index at admission and 24, 48 h after admission, and the mechanical ventilation time, the wound healing time, and the death ratio of patients in the two groups were recorded. The cardiac index, the global end-diastolic volume index (GEDVI), the intrathoracic blood volume index (ITBVI), the extravascular lung water index (EVLWI), and the systemic vascular resistance index (SVRI) of patients in PiCCO monitoring group at post injury hour 24, 48, and 72 and the abnormal cases were recorded. Data were statistically analyzed with Fisher's exact probability test, independent-sample or one-sample t test, analysis of variance for repeated measurement, and Bonferroni correction. Results: During the first 24 h post injury, the colloids coefficients of patients in PiCCO monitoring group was (0.69±0.15) mL·kg(-1)·%TBSA(-1), which was significantly less than (0.85±0.16) mL·kg(-1)·%TBSA(-1) in routine monitoring group (t=-2.612, P<0.05). Compared with the rehydration formula value of the Third Military Medical University for shock period, only the colloids coefficient of patients in routine monitoring group during the first 24 h post injury was significantly increased (t=2.847, P<0.05). There were no statistically significant differences between the two groups in the colloids coefficients of patients during the second 24 h post injury, or the electrolyte coefficients, the total rehydration coefficients, the urine volumes of patients during the first and the second 24 h post injury (t=0.579, -0.011, 0.417, -1.321, -0.137, 0.031, 1.348, P>0.05). The lactic acid level, the base excess level, the oxygenation index of patients at admission and 48 h after admission, and the oxygenation index of patients at 24 h after admission between the two groups were similar (t=-1.837, 0.620, 0.292, -1.792, 1.912, -0.167, 1.695, P>0.05). The levels of lactic acid and base excess of patients in PiCCO monitoring group were (4.8±1.4) and (1.2±5.5)mmol/L, respectively, which were significantly better than (7.0±1.5) and (-2.8±3.0) mmol/L in routine monitoring group at 24 h after admission (t=-3.904, 2.562, P<0.05 or P<0.01). There were no statistically significant differences between the two groups in the mechanical ventilation time or the wound healing time of patients (t=-0.699, -0.697, P>0.05), or the death ratio of patients (P>0.05). In PiCCO monitoring group, the GEDVI, and the ITBVI of patients were lower than the normal low values at post injury hour 24 and 48, which were in the normal range at post injury hour 72; the cardiac index of patients increased gradually and recovered to normal at post injury hour 48; the SVRI of patients increased significantly at post injury hour 24 and then gradually decreased to normal; the EVLWI average of patients at all time points post injury were less than 10 mL/kg. At post injury hour 24, most of the hemodynamic parameters of more than or equal to 8/15 patients in PiCCO monitoring group were abnormal, and the abnormal proportion decreased later. Conclusions: On the basis of traditional monitoring indicators, the use of PiCCO monitoring technology combined with the patient's condition (without pursuing normal levels of the parameters) in guiding the fluid resuscitation in severe burn patients can reduce the usage of colloid and better improve tissue perfusion, with the resuscitation effect being better than conventional monitoring.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Zhonghua shao shang za zhi = Zhonghua shaoshang zazhi = Chinese journal of burns
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.