Abstract

A pressure sensitive paint (PSP) measurement has been known as a pressure field measurement technique based on the oxygen quenching phenomenon of luminescence of specific luminophores. A PSP measurement was applied for pressure field measurement in a low-solidity circular cascade diffuser of a single-stage transonic centrifugal compressor with 5 in pressure ratio for HFC134a gas. The oxygen concentration was about 500 ppm. Ru (bath-phen) was adsorbed on a silica-gel thin-layer chromatography sheet, and the sheet was pasted onto the side-wall between the cascade vanes. A drastic change in luminescent intensity was recognized during a surge condition. Also the pressure variations based on luminescent intensity agreed well with the pressure fluctuations measured using a semiconductor pressure sensor with high-frequency-response. It was shown that a PSP measurement worked well to investigate the unsteady pressure fields in a circular cascade diffuser of a transonic centrifugal compressor. Moreover, the time response of PSP becomes clear as a problem to be overcome for the present.