Abstract

In the past study the plastic region tightening has been applied to the bolted flange joint with smaller nominal diameter and its advantages have been demonstrated, however, behavior of the bolted flange joint with larger diameter is not investigated. Flange rotation of the bolted flange joint with large diameter increases when the internal pressure is applied. Gasket stress is not uniform and it may cause leak accident. So, it is necessary to investigate the behavior of the larger diameter flange. The present paper describes the behavior of bolted flange joint with large diameter under plastic region tightening. Firstly, API 20-inch flange joint tightened to the plastic region by bolt with a smaller diameter and superiority in the uniformity of the axial bolt force is demonstrated. And then the internal pressure is applied to the bolted flange joint and the behavior of the additional axial bolt force is demonstrated. The axial bolt force decreases with increasing the internal pressure, and the load factor is negative due to increasing of the flange rotation. However, the load factor of the bolted flange joint tightened to the plastic region by using the bolt with the smaller diameter approached zero. Using the bolts with smaller diameter is advantageous to the flange joint with the larger diamter, whose load factor is negative, to prevent the leakage. Additionally, the leak rate from the bolted flange joint is measured and the sufficient sealing performance is obtained.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call