Abstract

Most reservoirs built in earlier years in China generally have major safety issues and leakage is a common problem with them. Nowadays as the technology of Non-Destructive Testing (NDT) has developed and matured greatly, it has been widely used in detecting internal seepage channels, voids, cracks of the dam body and is showing obvious advantages in these aspects. This paper employed a method integrating geological radar (geo-radar) with ultrasonic detection to conduct safety test on the dam body of the Xidachuan Reservoir located in the Linjiang City of Jilin Province of China. The NDT discovered main leakage risk positions of the dam, gave a safety evaluation of the dam body, and proposed targeted treatment measures. NDT can quickly and accurately inspect the quality problems with the dam without causing damages to the structure and it can provide reliable guarantees for the quality of dam projects.