Abstract

In order to explore spectral standardization methods for spectra collected by different NIR spectrometers, to reduce spectral differences, and to realize model sharing among different instruments, the crude protein content of 154 wheat flour samples was measured using one grating and three Fabry-Perot tunable filter NIR spectrometers in wavelength. At the same wavelength range and wavelength interval, three algorithms, namely, direct standardization (DS), piecewise direct standardization (PDS), and simple linear regression direct standardization (SLRDS), were used to standardize spectra collected by different instruments from the same samples. Spectral standardization error rate (SSER), principal component score error rate (PCSER), and other indicators were employed to analyze the spectral differences between the master and the target spectra, and the effect of model sharing was evaluated using parameters including prediction correlation coefficient (Rp), root mean square error of prediction (RMSEP), and relative prediction deviation (RPD). The results show the following: (1) The difference between spectra can be quantitatively evaluated through analyzing SSER and PCSER. (2) After standardization by the three algorithms, the spectral difference between the three target and the master spectrometers is significantly reduced and the prediction effect of the master model is greatly improved. (3) Among the three algorithms, DS algorithm had the smallest error rate in standardizing spectra from three target spectrometers. After standardization by the DS algorithm, the master model had the best effect. Its prediction accuracy was greatly improved compared with that before standardization. (4) The standard model established based on the S450 spectrometer can be applied to the same spectrometer as the N500 spectrometer with the same resolution and different wavelength ranges, so as to achieve model sharing. Therefore, DS, PDS, and SLRDS algorithms can effectively reduce the spectral differences between different instruments and realize the sharing of NIR calibration models for wheat flour crude protein measurement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.