Abstract
A method has been developed for the direct determination of copper in petroleum condensate using detergentless micro-emulsions (three-component solutions) and graphite furnace atomic absorption spectrometry. The optimization was performed using a three-level full factorial design, resulting in pyrolysis and atomization temperatures of 920 °C and 2600 °C, respectively. Using the secondary copper line at 327.4 nm, which is less affected by the magnetic field of the Zeeman-effect background correction system, a characteristic mass of 39 pg, and detection limit of 0.4 μg l−1 was obtained using 20 μl of micro-emulsion, which corresponds to 1.2 μg l−1 in petroleum condensate. The precision, expressed as relative standard deviation, was 2.0% or 2.8% for copper concentrations of 30 μg l−1 and 5.0 μg l−1, respectively. The spike recovery of 105% for copper added to a petroleum condensate sample proved that this procedure could be applied satisfactorily to a determination in this matrix.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.