Abstract

Helium line intensities have been utilized to measure the electron density, n e , and temperature, T e , by comparing measured line intensities to a collisional-radiative model (CRM). In this study, we use multiple regression analysis to train a model of the helium line intensities and n e /T e obtained from a Thomson scattering system in the linear plasma device Magnum-PSI; based on the trained model, we predict n e and T e from line intensities. We show that this method can also obtain radial profiles of n e and T e . We discuss appropriate selections of line pairs for the prediction based on the multiple regression analysis. A big advantage of this method against the standard technique using CRM is that modeling of atomic population distributions is not required, which sometimes needs to take into account various effects such as radiation trapping, transport of helium atoms in metastable states, etc.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.