Abstract

Objective To evaluate the performance of micro-flow imaging(MFI)in the differential diagnosis of benign and malignant thyroid nodules. Methods Totally 50 patients with thyroid nodules examined by conventional ultrasound,MFI,and contrast-enhanced ultrasound and confirmed by histological or cytological pathology in the First Medical Center of Chinese PLA General Hospital from May to December in 2020 were enrolled in the study.The clinical data and ultrasound images were retrospectively analyzed.A binary logistic regression model was established to evaluate the performance of the model in predicting benign and malignant thyroid nodules. Results Logistic regression showed that composition and "S-W-C" sign were independent risk factors for predicting malignant thyroid nodule.The sensitivity,specificity,and Youden index of the logistic regression model were 73.33%,80.00%,and 0.53,respectively,and the area under receiver operating characteristic curve was 0.799(95%CI=0.662-0.899). Conclusion MFI facilitates the differential diagnosis of benign and malignant thyroid nodules and has the potential to be applied in the future.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.