Abstract

Objective To evaluate the application of two-dimensional magnetization-prepared true fast imaging with steady-state precession(2D-MP-TrueFISP)sequence in brain tumor enhancement.Methods In this study,60 cases of brain tumor patients who underwent enhanced magnetic resonance imaging of brain were scanned with 2D-MP-TrueFISP/two-dimensional spoiled gradient-recalled echo(2D-SPGR)before and after enhancement.The scores of lesions on the images of 2D-MP-TrueFISP/2D-SPGR were compared.At the same level of 2D-SPGE and 2D-MP-TrueFISP,the signal intensities(SIs)of lesions,white matter,and cerebrospinal fluid were measured before and after enhancement,and the contrast ratios(CRs)of lesions were calculated.The CRs before and after 2D-SPGR/2D-MP-TrueFISP enhancement and those between 2D-SPGR and 2D-MP-TrueFISP after enhancement were compared.Results The scores of lesions after 2D-MP-TrueFISP/2D-SPGR T1WI enhancement were 9.0(9.0,9.0)and 7.0(6.0,7.0),respectively,with significant difference(Z=-6.86,P=0.00).CRs showed significant difference before and after enhancement with 2D-SPGR and 2D-MP-TrueFISP(all P<0.01).The CRs of lesion compared with white matter and cerebrospinal fluid(1.58±0.46 and 8.50±2.47,respectively)after 2D-MP-TrueFISP enhancement were significantly higher than those[0.57±0.29(t=-17.38,P=0.00)and 2.64±0.85(t=-19.71,P=0.00),respectively]after 2D-SPGR enhancement.Conclusion Compared with 2D-SPGR,2D-MP-TrueFISP demonstrated improved enhancement and uniformity as well as clear boundary and display of edema around the lesion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call