Abstract

PurposeDynamic in-situ proton (1H) magnetic resonance imaging (MRI) and 1H T2-relaxometry experiments are described in an attempt to: (i) understand the physical processes, that occur during the reconstitution of lyophilized bovine serum albumin (BSA) and monoclonal antibody (mAb) proteins; and (ii) objectify the reconstitution time.MethodsRapid two-dimensional 1H MRI and diffusion weighted MRI were used to study the temporal changes in solids dissolution and characterise water mass transport characteristics. One-shot T2 relaxation time measurements were also acquired in an attempt to quantify the reconstitution time. Both MRI data and T2-relaxation data were compared to standard visual observations currently adopted by industry. The 1H images were further referenced to MRI calibration data to give quantitative values of protein concentration and, percentage of remaining undissolved solids.ResultsAn algorithmic analysis of the 1H T2-relaxation data shows it is possible to classify the reconstitution event into three regimes (undissolved, transitional and dissolved). Moreover, a combined analysis of the 2D 1H MRI and 1H T2-relaxation data gives a unique time point that characterises the onset of a reconstituted protein solution within well-defined error bars. These values compared favourably with those from visual observations. Diffusion weighted MRI showed that low concentration BSA and mAb samples showed distinct liquid-liquid phase separation attributed to two liquid layers with significant density differences.ConclusionsT2 relaxation time distributions (whose interpretation is validated from the 2D 1H MR images) provides a quick and effective framework to build objective, quantitative descriptors of the reconstitution process that facilitate the interpretation of subjective visual observations currently adopted as the standard practice industry.

Highlights

  • Lyophilization is a unit operation used extensively in the biopharmaceutical industry aimed at producing dry stable protein formulations containing 0.1–4% water, thereby increasing the stability and shelf life of the product [1,2,3,4,5]

  • T2 relaxation time distributions provides a quick and effective framework to build objective, quantitative descriptors of the reconstitution process that facilitate the interpretation of subjective visual observations currently adopted as the standard practice industry

  • In this paper we report the use of rapid single-shot onedimensional (1D) 1H nuclear magnetic resonance (NMR) T2– relaxation time measurements combined with fast 2D 1H magnetic resonance imaging (MRI) methods as a noninvasive tool for monitoring the reconstitution process within a standard lyophilized sample vial

Read more

Summary

Results

An algorithmic analysis of the 1H T2-relaxation data shows it is possible to classify the reconstitution event into three regimes (undissolved, transitional and dissolved). A combined analysis of the 2D 1H MRI and 1H T2-relaxation data gives a unique time point that characterises the onset of a reconstituted protein solution within welldefined error bars. These values compared favourably with those from visual observations. Conclusions T2 relaxation time distributions (whose interpretation is validated from the 2D 1H MR images) provides a quick and effective framework to build objective, quantitative descriptors of the reconstitution process that facilitate the interpretation of subjective visual observations currently adopted as the standard practice industry.

INTRODUCTION
71 Page 2 of 21
71 Page 4 of 21
71 Page 6 of 21
RESULTS & DISCUSSION
71 Page 8 of 21
71 Page 10 of 21
71 Page 12 of 21
71 Page 14 of 21
71 Page 16 of 21
71 Page 18 of 21
CONCLUSIONS AND OUTLOOK
71 Page 20 of 21
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call