Abstract

A non destructive testing technique – so called modulated photothermal thermography or lock-in thermography – has been set-up for plasma facing components examination. Reliable measurements of phase contrast were obtained on 8 mm carbon fiber composite (CFC) armoured W7-X divertor component with calibrated flaws. A 3D finite element analysis allowed the correlation of the measured phase contrast and showed that a 4 mm strip flaw can be detected at the CFC/copper interface.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.