Abstract
Abstract In this paper, the problem of air cooling and temperature nonuniformity at the cell and pack level is addressed. Passive techniques are developed by integrating jet inlets and vortex generators (VGs) in a simple battery pack with the goal to achieve an effective cooling, and the desired temperature uniformity at the cell and pack level to less than 5 °C, without an increase in the required mass flow and power requirements. Moreover, various configurations of the developed techniques are assessed and compared. In order to achieve the objectives, computational fluid dynamics (CFD) is used to conduct numerical studies on the battery packs. The results concluded that by adding both the delta winglet (DW) vortex generator arrays and jet inlet arrays in the same configuration, improvements in temperature reduction and uniformity can be achieved. The results showed that the maximum temperature of the battery pack was reduced by ∼6% and the temperature uniformity at the pack level was increased by 24%. Additionally, a ∼37% improvement in the temperature uniformity at cell level was achieved.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Thermal Science and Engineering Applications
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.