Abstract

OBJECTIVE. The purpose of this study is to retrospectively assess the impact of iterative metal artifact reduction (IMAR) with iterative reconstruction (IR) on the image quality and diagnostic performance of CT urography in the evaluation of patients with hip prostheses, compared with IR alone. MATERIALS AND METHODS. CT urography examinations that were reconstructed using IR with and without IMAR were analyzed for 57 patients (29 women and 28 men; mean age, 74 years [range, 22-94 years]) with hip prostheses (40 unilateral and 17 bilateral). For quantitative analysis, image noise within the bladder was measured. Two radiologists (radiologist 1 [RAD1] and radiologist 2 [RAD2]) qualitatively evaluated the images using both a 5-point scale to assess the degree of visualization of artifacts and a 6-point scale to determine diagnostic confidence in visualization of the bladder, ureters, prostate or uterus, pelvic calcifications, and genitourinary abnormalities involving the bladder, distal ureters, prostate, uterus, and ovaries. RESULTS. The combination of IMAR and an IR technique provided improvement in quantitative and qualitative measurements (p < 0.05). Forty-three genitourinary abnormalities were detected in 29 patients. Quantitative and qualitative comparisons of scans obtained with and without the use of IMAR, respectively, revealed image noise of 99.6 versus 173.3 HU and the following radiologist scores: for improvement of artifacts, 3.2 versus 1.6 (for RAD1) and 3.1 versus 1.6 (for RAD2); for visualization of the bladder, 3.6 versus 1.5 (RAD1) and 3.8 versus 1.6 (RAD2); visualization of the ureters, 3.8 versus 1.6 (RAD1) and 3.9 versus 1.7 (RAD2); visualization of the uterus, 4.3 versus 2.8 (RAD1) and 4.3 versus 2.6 (RAD2); visualization of the prostate, 4.5 versus 2.3 (RAD1) and 4.5 versus 2.2 (RAD2); diagnostic confidence for calcifications, 4.7 versus 3.5 (RAD1) and 4.7 versus 3.3 (RAD2); and diagnostic confidence for genitourinary abnormalities, 5.0 versus 3.2 (RAD1) and 4.8 versus 2.9 (RAD2), respectively. CONCLUSION. The addition of IMAR to IR led to statistically significant improvement in the retrospective diagnostic performance and image quality of CT urography for patients with hip prostheses, compared with IR alone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.