Abstract

Free carrier concentration profiles were determined by Fourier Transform Infrared (FTIR) variable angle spectroscopic ellipsometry. The technique exploits carrier absorption in the mid-infrared spectral range and combines the sensitivity of ellipsometry with a simple Drude free carrier absorption model to determine the carrier profile. In this study, the carrier profiles were modeled as graded multilayers that were constrained to a specific functional form (e.g. Gaussian, complementary error function) when appropriate. Carrier profiles from boron and arsenic ion-implanted that had been subjected to furnace or Rapid Thermal Annealing (RTA) annealed silicon wafers were compared to Spreading Resistance Probe and Secondary Ion Mass Spectrometry profiles. p−p+doped epitaxial silicon samples (before and after annealing) were also measured and the results were compared to theory.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.