Abstract
A cloud point extraction method has been developed using an ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate, BMiM PF 6) for the determination of a widely studied cyanotoxin (microcystin leucine–arginine, MCLR) in natural waters. Extraction parameters such as sample pH, extraction temperature, extraction time, the amount of ionic liquid and the amount of extraction volume were investigated and optimized to achieve the maximum extraction efficiency. The results obtained indicated a good linearity with the correlation coefficient of 0.995 over the range of 0.5–50 μg L −1. The relative standard deviation (RSD) of the method was 7.5% ( n = 6). The calculated method detection limit was 0.03 μg L −1 ( n = 6). The practical applicability of the technique was demonstrated by analyzing water samples ( n = 9) collected from three different sites in local reservoirs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.