Abstract
Automatic transfer switch (ATS) is useful for integrating two different energy sources can be applied to e-bike charging stations. Renewable energy sources from sunlight using 2×100 Wp photovoltaic (PV) modules as the main source in this study, as well as grid energy sources functioned as backup energy. This ATS uses inverter input rating methods and standard AC voltage drop/over, a novelty of this study. The amount of current during testing is up to 14.09 A. The value of the inverter input voltage affects the quality of the inverter output voltage, there is a stability of the inverter output voltage from the AC voltage standard ±5% of the, lowest voltage value of (Vo_inv) = 223.9 V and the highest value (Vo_inv) = 226.1 V, at the time of (Vi_inv) max = 14.15 V and (Vi_inv) min = 12.66 V. It can be concluded that the ATS works in the PV position of the supply to the e-bike load, in the PV state it can produce power of a maximum value of 135.9 W at 11:25 am and is at the lowest power of 31 W at 03:31 pm. This ATS device in the switch mode successfully implemented a duration range of 10-21 ms, during the transfer of energy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Power Electronics and Drive Systems (IJPEDS)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.