Abstract

Stress corrosion damage has a great proportion in modern machine engineering. The danger resulted from it is because corrosion crack is fine and not easy to be found by eyes. Therefore, it's important to study stress corrosion fracture in the field of engineering fracture mechanics. In this paper, the real-time method and double-exposure method in holographic interferometry are used to monitor and measure crack extension procedure in high-strength steel placed in corrosion environment, and record holographic interferogram. The test results indicate that this method can display clearly change procedure of strain interference fringes at crack-tip, determine stress corrosion fracture starting point of stress corrosion and K<SUB>ISCC</SUB>. Compared with other methods, it has obvious advantages.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.