Abstract

This study aims to develop a rapid, simple, precise, and accurate high-performance liquid chromatographic (HPLC) method to determine levodopa (LD), carbidopa (CD), and entacapone (EN) mixture in their pharmaceutical dosage forms. The developed method was validated for specificity, linearity, precision, and accuracy. The specificity of the method was determined in the presence of placebo interference and different degradation products. The response was linear for the drug concentration ranges of 1.25–500.00, 0.31–125.00, and 2.500–850.00 µg mL−1 for LD, CD, and EN, respectively. Accuracy values for the method ranged from 99.20–100.80, 99.30–100.70, and 98.85–101.16% for LD, CD, and EN, respectively. The dissolution of the pharmaceutical products carlidopa 12.5 mg and carlidopa 37.5 mg tablets was tested and reported.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.