Abstract

To investigate the application of high-intensity focused ultrasound (HIFU) for fetal umbilical artery blood flow occlusion in a rabbit model. A prototype HIFU transducer in combination with an imaging probe with Doppler capability was constructed. Using this transducer, HIFU was applied at 1.4, 2.75 or 5.5 kW/cm(2) through the maternal abdominal skin to the fetal intra-abdominal umbilical arteries of four time-mated Japanese White rabbits (11 fetuses) on gestational day 25. Courses of 5-s HIFU exposure were performed until cessation of umbilical blood flow and cardiac arrest were confirmed by Doppler ultrasonography. Fetal necropsy was performed and exposed lesions were assessed by microscopic histological analysis. The mean diameter of the fetal umbilical artery was 0.6 +/- 0.2 mm and the mean peak systolic velocity of arterial blood flow was 44.7 +/- 18.5 cm/s. When HIFU was applied at 5.5 kW/cm(2), blood flow was completely occluded within 15 courses. HIFU exposure brought about vacuolar degeneration and destruction of elastic fibers in the tunica media of the artery. HIFU can be used to occlude umbilical artery blood flow in fetal rabbits.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.