Abstract

We successfully applied high frequency scanning acoustic microscopy (SAM) as a tool for the analysis of MEMS sensors. Using state of the art transducers with frequencies up to 300MHz, we evaluated the achievable resolution and performed case studies: we localized a contamination-induced delamination on the ASIC surface and studied failure modes after mechanical stability tests, showing that a combination of SAM and infrared microscopical evaluation provides information about the course of cracks on a micrometer length scale.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.