Abstract

The results of four cylinder tests performed on two batches of the HMX based explosive EDC37 using a new suite of diagnostics are described. Heterodyne laser velocimetry (het-v) and pyrometry were fielded for the first time on cylinder tests within AWE. Pyrometry gave a measurement of the temperature of the detonating HE of 2600-3485 K. Sixteen channels of het-v were fielded and provided high fidelity expansion data at distances of up to 30 mm. High speed framing camera images were obtained and show no signs of cylinder break up or spallation until distances greater then 35 mm. The het-v expansion data made it possible to resolve up to 8 shock reverberations in the wall as it expands. The expansion of the cylinder wall was recorded both before and after steady state detonation was reached and the results compared. Het-v probes were fielded at different angles to the expanding cylinder wall allowing both the vertical and horizontal expansion velocity to be determined. The extra information that these cylinder tests yielded will allow for more accurate code validation and determination of the equation of state of the explosive products.