Abstract

The application of biocalorimetry to fermentation processes offers advantageous insights, while being less complex compared to other, sophisticated PAT solutions. Although the general concept is established, calorimetric methods vary in detail. In this work, a special approach, called heat compensation calorimetry, was applied to an E. coli fed-batch process. Much work has been done for batch processes, proving the validity and accuracy of this calorimetric mode. However, the adaption of this strategy to fed-batch processes has some implications. In the first section of this work, batch fermentations were performed, comparing heat capacity calorimetry to the compensation mode. Both processes showed very good agreement by means of growth behavior. The heat related differences, e.g. temperature profiles, were obvious. In addition, the impact of the chosen mode on the calculation of in-process heat transfer coefficients was shown. Finally, a fed-batch fermentation was performed. The compensation mode was kept sufficiently, up to the point where the metabolic heat production accelerated strongly. Controller tuning was a neuralgic point, which would have needed further optimization under these conditions. Nevertheless, in the present work it was possible to realize a working compensation process while demonstrating critical aspects that must be considered when establishing such approach.