Abstract

In this work, gas–liquid distributions in an industrial centrifugal pump operated at various steady state conditions have been quantitatively determined. Therefore, high-resolution gamma-ray computed tomography (HireCT) has been applied, operated in time-averaging rotation-synchronized CT scanning mode. Detailed studies have been performed on a hydraulic test facility providing authentic operating conditions for industrial centrifugal pumps. The gas phase distribution in the centrifugal pump has been studied for swirling gas–liquid two-phase flow as an inlet flow regime and at defined inlet gas volumetric flow rates between 0% and 5%. In this way, the influence of the inlet flow boundary conditions on the performance of the centrifugal pump as well as the gas holdup distribution within the impeller region could be successfully determined.