Abstract

This paper employs an extended Kalman filter (EKF) to estimate the rotor position and speed of a vector controlled surface-mounted permanent magnet (PM) brushless AC (BLAC) motor from measured terminal voltages and currents only. Both full-order and simplified EKFs are employed and their simulated performance capabilities are compared. Excellent agreement is achieved between estimated and commanded results. The EKF is also employed to identify the stator flux-linkage due to the PMs, which is influenced by temperature variation and magnetic saturation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.