Abstract
Forced oscillating combustion can reduce nitrogen oxides (NOx) as described by the previous research. In this paper, we applied this method to two kinds of radiant tube burner in order to confirm the effect of NOx reduction. Fuel is supplied through a solenoid valve which is made open and shat several times a second with various duty ratios. Flow rate of the fuel, temperature of the furnace and air ratio are switched to investigate the effect. About 30% of NOx reduction is observed under acceptable performance of combustion and this method is proved to be applicable to many combustion appliances.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.