The purpose of this study was to investigate the performance of Er:YAG laser when used with a tip curved at 100° in retrograde cavity preparation. Ten extracted single-rooted human teeth, prepared and obturated using the lateral condensation method, were resected 3 mm from the apex. Retrograde cavities were prepared using either an Er:YAG laser or an ultrasonic unit. There was no significant difference between the two methods with respect to working time and postoperative increase in the root canal area. In conclusion, retrograde cavity preparation performed with the Er:YAG laser is as effective as with the ultrasonic retro-tip.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.