Abstract
To explore the application value of applying deep learning (DL) algorithm in the grading assessment of corneal fluorescein staining. A cross-sectional study was carried out, covering 600 corneal fluorescein staining photos acquired in the Contact Lens Clinic, West China Hospital, Sichuan University between 2020 and 2022. Out of the 600 photos, 500 were used to construct the algorithm and the remaining 100 were used for the validation of the algorithm and a comparative analysis of the difference in grading accuracy (ACC) and the length of diagnostic time between artificial intelligence (AI) and optometry students. One month after finishing the first grading analysis, assessment by AI and optometry students was conducted for a second time and results from the two rounds of assessment were compared to examine the intrarater agreement ( kappa value) of the two analyses. The grading analysis results of 3 experienced optometrists were used as the gold standard in the study. Findings of the cross validation with the complete dataset, the training dataset, and the test dataset showed that ResNet34 had the highest predictive accuracy among four DL models. ResNet34 DL model achieved an accuracy of 93.0%, sensitivity of 89.5%, and specificity of 89.6% in the grading of corneal staining. In the comparison of the grading accuracy of AI and two optometry students, AI showed better accuracy, with the respective grading accuracy being 87.0%, 78.0%, and 52.0% for AI, student 1, and student 2 ( P ACC=0.001). In addition, the average diagnostic time of AI was shorter than that of optometry students ( t AI=1.00 s, t S1=11.86 s, t S2=13.25 s, P t =0.001). In the comparative analysis of the intrarater agreement between the two assessments, AI ( kappa AI=0.658, P AI=0.001) achieved better consistency than the two optometry students did ( kappa S1=0.575, P S1=0.001; kappa S2=0.609, P S2=0.001). Applying deep learning algorithms in the grading assessment of corneal fluorescein staining has considerable feasibility and clinical value. In the performance comparison between AI and optometry students, AI achieved higher accuracy and better consistency, which indicates that AI has potential application value for assisting optometrists to make clinical decisions with speed and accuracy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.