Abstract

To investigate the application of computer aided design-computer aided manufacture (CAD-CAM) technique in the reconstruction of mandible defect with individual titanium prosthesis. Six patients with large mandibular ramus and angle tumor were spiral CT scanned preoperatively, and the CAD-CAM was used to design and make individual titanium prosthesis for reconstructing the mandibular defects after resection of the tumor. The prosthesis were assembled during operation. Postoperative follow-up period was 9 - 38 months. The design and manufacture of titanium prosthesis by use of CAD-CAM technique was convenient and the prosthesis fitted the defects very well. The outline of the face, the occlusion and function were restored. After 9 - 38 months of follow-up, the mandibular symmetry was good. The application of CAD-CAM provided accurate simulation and fast manufacturing process for the titanium prosthesis in the repair of mandibular defect.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.