Abstract

Selective catalytic reduction (SCR) with ammonia or urea is regarded as one of the most important technologies to reduce the NOx emissions from coal-fired power plants. However, the design and development of SCR–DeNOx systems are a complicated process involving the optimization of several parameters such as the ammonia/urea injection strategy, the installment of the gate leaf and the hybrid grid, as well as the thickness of straightener. These parameters determine the velocity and concentration distributions at the entrance of catalyst layers, which are key factors to affect the efficiency of flue gas denitrification and ammonia slip. In this work, CFD simulations are carried out to portray the performance of the SCR–DeNOx facility in a 300MW coal-fired power plant. The influences of the gate leaf, hybrid grid and straightener on the distributions of the velocity and concentration are investigated. And then the corresponding experiments are performed to qualitatively confirm the simulation results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.