Abstract
In this paper, a rapid, selective and effective technique, pipette-tip solid phase extraction based on molecularly imprinted polymer, was used for extraction and pre-concentration of methyl red (MR) prior to its determination by spectrophotometer. Variables influencing extraction efficiency including type and volume of eluent solvent, sample volume, number of cycles of extraction and elution, amount of sorbent and pH of the sample solution were optimized with two methods of one-variable-at-a-time and response surface methodology (RSM). For RSM optimization, seven factors in three-levels were utilized for Box-Behnken experimental design. Under optimum conditions, a linear calibration graph in the range of 3.0–300.0 μg L−1 for MR was resulted. The limit of detection of proposed method was 0.50 μg L−1 for MR. Finally, the investigated method was used for the determination of MR in seawater and the mean recoveries were calculated to be 84.0–98.0% with mean RSD of 2.5–6.7%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.