Abstract
Prediction of the Critical Heat Flux (CHF) for upward flow of water in uniformly heated vertical round tube is studied with Artificial Neuron Networks (ANNs) method utilizing different neuron number in hidden layers. This study is based on thermal equilibrium conditions. The neuron number in hidden layers is chosen to vary from 5 to 30 with the step of 5. The effect due to the variety of the neuron number in hidden layers is analyzed. The analysis shows that the neuron number in hidden layers should be appropriate, too less will affect the prediction accuracy and too much may result in abnormal parametric trends. It is concluded that the appropriate neuron number in two hidden layers should be [15 15] in the article.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.