A novel hybrid series active power filter to eliminate harmonics and compensate reactive power is presented and analyzed. The proposed active compensation technique is based in a hybrid series active filter using adaptive Tabu search (ATS) algorithm in the conventional Sinusoidal Fryze voltage (SFV) control technique. Optimization of the conventional Sinusoidal Fryze voltage control technique has been done using adaptive tabu search algorithm. This paper discusses about the comparative performances of conventional Sinusoidal Fryze voltage control strategy and ATS-optimized controllers. ATS algorithm has been used to obtain the optimum value of Kp and Ki. Analysis of the hybrid series active power filter system under non linear load condition and its impact on the performance of the controllers is evaluated. Effectiveness of the hybrid series active power filter to provide harmonic damping is demonstrated by MATLAB/Simulink results. Total harmonic distortion (THD) demonstrates the practical viability of the controller for hybrid series active power filter to provide harmonic isolation of non-linear loads and to comply with IEEE 519 recommended harmonic standards.