Abstract

IntroductionCircumferential endoscopic submucosal dissection (ESD) allows to treat large esophageal superficial neoplasms, however with a high occurrence of severe esophageal strictures. In a previous work, we demonstrated that the application of a prototype of self-assembling peptide (SAP) matrix on esophageal wounds after a circumferential-ESD delayed the onset of esophageal stricture in a porcine model. The aim of this work was to consolidate these results using the commercialized version of this SAP matrix currently used as a hemostatic agent.Animals and methodsEleven pigs underwent a 5 cm-long circumferential esophageal ESD under general anesthesia. Five pigs were used as a control group and six were treated with the SAP. In the experimental group, 3.5 mL of the SAP matrix were immediately applied on the ESD wound. Stricture rates and esophageal diameter were assessed at day 14 by endoscopy and esophagram, followed by necropsy and histological measurements of inflammation and fibrosis in the esophageal wall.ResultsAt day 14, two animals in the treated group had an esophageal stricture without any symptom, while all animals in the control group had regurgitations and an esophageal stricture (33 vs. 100%, p = 0.045). In the treated group, the mean esophageal diameter at day 14 was 9.5 ± 1 mm vs. 4 ± 0.6 mm in the control group (p = 0.004). Histologically, the neoepithelium was longer in the SAP treated group vs. the control (3075 μm vs. 1155μm, p = 0.014). On immunohistochemistry, the expression of alpha smooth muscle actin was lower in the treated vs. control group.ConclusionApposition of a self-assembling peptide matrix immediately after a circumferential esophageal ESD reduced by 67% the occurrence of a stricture at day 14, by promoting reepithelialization of the resected area.

Highlights

  • Circumferential endoscopic submucosal dissection (ESD) allows to treat large esophageal superficial neoplasms, with a high occurrence of severe esophageal strictures

  • Apposition of a self-assembling peptide matrix immediately after a circumferential esophageal ESD reduced by 67% the occurrence of a stricture at day 14, by promoting reepithelialization of the resected area

  • Our aim is to assess PuraStat, the commercially available version of the self-assembling peptide (SAP) which is at pH = 2, as a wound dressing for the prevention of esophageal stricture after circumferential ESD

Read more

Summary

Introduction

Circumferential endoscopic submucosal dissection (ESD) allows to treat large esophageal superficial neoplasms, with a high occurrence of severe esophageal strictures. We demonstrated that the application of a prototype of self-assembling peptide (SAP) matrix on esophageal wounds after a circumferential-ESD delayed the onset of esophageal stricture in a porcine model. The aim of this work was to consolidate these results using the commercialized version of this SAP matrix currently used as a hemostatic agent. Eleven pigs underwent a 5 cm-long circumferential esophageal ESD under general anesthesia. Five pigs were used as a control group and six were treated with the SAP. 3.5 mL of the SAP matrix were immediately applied on the ESD wound. Stricture rates and esophageal diameter were assessed at day 14 by endoscopy and esophagram, followed by necropsy and histological measurements of inflammation and fibrosis in the esophageal wall

Objectives
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call