Abstract

The results of using a specially developed collimated dosimetric system, placed on a Brokk-90 remote-controlled machine, to survey a spent fuel storage facility are presented. The measuring block of the system consists of collimated and uncollimated γ-ray detectors, video cameras, and headlights. The range of the dose-rate measurements of the γ-ray detectors varies from 0.4 mSv/h to 8.5 Sv/h. The collimation angle of the collimated detector is 12° and the lead shielding is 30 mm thick. The system made it possible to perform this work in large radiation fields by remote means. The dose rate distribution along extended elements, extracted from the spent fuel storage facility in the MR hall, is obtained. The contents of the storage facility were visualized in all details. Using the results of the survey, the contents of the storage facility were repacked and removed from the MR room.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.