Abstract

Abstract Three pedestrian portal monitor systems, designed to detect illicit trafficking or inadvertent movement of radioactive materials carried by passengers at airports, have been evaluated. The systems were supplied by three manufacturers: Bicron, Exploranium and Thermo-Eberline. In an initial evaluation, conducted at the Laboratory of Nuclear Engineering of the School of Civil Engineering, it was observed that the FHT-1372 system manufactured by Thermo-Eberline gave a more sensitive response and allowed the measurement of total photon dose rate and artificial photon dose rate. Therefore, this system was installed at Barajas International Airport in Madrid in 2002 for a period of 108 days in order to select an appropriate investigation level (defined as the radiation level that is selected as the trigger for further investigation). During this period 1,339,931 passengers were screened and a total of 39 alarms were triggered, 5 of which with a value 10 times the mean value of the natural background from photon radiation (which was 85 nSv/h), and no alarms exceeded 100 μSv/h at 1 m distance, which is the level of response for legal transport of radioactive materials set by the International Atomic Energy Agency (IAEA). An investigation level of approximately 1.3 times the natural background was finally selected. This value coincides with the results obtained in the ITRAP (Illicit Trafficking Radiation Detection Assessment Program) carried out by the IAEA.