Abstract

In this paper, in view of the non minimum phase characteristics of hydraulic turbine unit, a method of designing the controller of multi-input multi-output (MIMO) nonlinear non-minimum phase system is proposed and applied to hydraulic turbine unit system described by double control input fifth order model. The turbine output electromagnetic power and generator power angle are stabilized by wicket gate opening and excitation combined control. Firstly, the method for designing the controller of multi-input multi-output (MIMO) nonlinear non-minimum phase system is introduced. The method is based on state feedback theory, pole assignment theory and Lyapunov stability theory. Secondly, the control law of hydro turbine unit is given according to the method. Results of simulation indicate that this nonlinear non-minimum phase controller has a good effect when applied to the hydro turbine unit.