Abstract

Herein, a facile dispersive micro-solid phase extraction (d-µSPE) procedure using carboxylated multi-walled carbon nanotubes modified with silver nanoparticles (Ag/MWCNTs-COOH) was successfully developed for the adsorption and subsequent determination of low levels of two well-known contaminants, namely bisphenol A and S (BPA and BPS) in water and soft drink samples. The detection and measurement of the above-mentioned compounds were performed by HPLC-UV instrument. The applied d-µSPE procedure has several advantages such as rapidity, high degree of sensitivity, precision and efficiency. A combination of polar/non-polar interactions seems to play a key role in the adsorption process. Under the optimized conditions, the calibration curves were linear over the concentration range of 1–500 µg/L for the both targets. The practical limit of quantifications (LOQ) for the both analytes were determined to be 1.0 µg/L. The average relative recoveries obtained from the fortified samples varied between 92 and 110% with the relative standard deviations (RSD%) of 2.9–9.5%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.