Abstract
To investigate the effectiveness and safety of modified electrocardiogram (ECG)-guided technique in umbilical venous catheterisation in neonates. Sixty-six critically ill neonates underwent umbilical venous catheterisation with (ECG group) or without (control group) ECG guidance from January 2017 to March 2019. We retrospectively analysed and compared the rate of correct tip placement on first try, unplanned extubation rate and incidence of catheter-related complications between the two groups. There were 33 patients in each group. The ECG group showed significantly higher rate of correct tip placement on first try (P < 0.001), lower unplanned extubation rate (P < 0.001), but identical incidence of catheter-related complications (P = 0.492) comparing with the control group. The ECG-guided technique is an effective and safe method for umbilical venous catheterisation. The connecting method we modified made this technique more practical and can be promoted to areas without access to specific ECG adaptors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.