A rapid, simple and sensitive method based on ultra fast liquid chromatography-tandem spectrometry for the determination of buflomedil in human plasma has been developed and validated using carbamazepine as internal standard. After the precipitation of plasma sample with methanol, the analyte and IS were separated on an Ultimate C18 column (5μm, 2.1mm×50mm, MD, USA) with an isocratic mobile phase composed of acetonitrile and 5mM ammonium acetate in water (60:40, v/v) at a flow rate of 0.25ml/min. The analyte and IS were detected with proton adducts at m/z 308.3-237.1 and m/z 237.2-194.2 in positive ion electrospray ionization and multiple reaction monitoring acquisition mode, respectively. The lower limit of quantification of the method was 23.64ng/ml with a linear dynamic range of 23.64-1182ng/ml for buflomedil. The intra- and inter-batch precisions were less than 5.8%. The developed method was successfully applied to a bioequivalence study of two buflomedil hydrochloride preparations (150mg) in 22 healthy Chinese male volunteers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.