Abstract

This paper investigates the potential of 6LiI(Eu)/photodiode (PD) detector systems for application as neutron counters in radioisotope identification devices (RIID). Those are exposed to mixed neutron-gamma fields. An effective suppression of signals due to gamma interactions with the scintillator or the PD bulk material is of major importance since neutron alarms in RIID are triggered by a few single neutron counts; any gamma signal not rejected may generate a false neutron alarm. Measurements demonstrated that digital signal processing combined with simultaneous pulse height and pulse shape analysis can provide efficient neutron-gamma discrimination. The results were obtained with a compact, basic detector configuration and sampling rates of only 10 MS/s. Such systems can be realized with state-of-the-art miniaturized electronics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.