Abstract

For the application demonstration of cellulose triacetate (CTA) polymer film based transparent insulation (TI) structures a technically and ecologically optimized TI facade system was developed and used to equip a south-oriented wall of a solar house meeting passive house standard in Graz, Austria. The demonstration building was equipped with an appropriate data recording system for solar irradiation, temperature, heat flux and humidity. The practical experiences within the heating periods 2002/03 and 2003/04 are reported in this paper. For the optimized TI facade system a solar energy efficiency of about 43% and a U-value of 0.76 W/(m 2 K) were obtained. Although CTA absorbs a high amount of water no adverse condensation phenomena were observable visually. The reasoning for these findings is explained and related to construction details.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.